7030B Auto Pressure Calibrator Module
- Description
- Reviews (0)
Description
The 7030B is a high speed pressure controller/calibrator module suitable for wide workload calibration of pressure devices such as transmitters, sensors and gauges. Models can be configured for ranges from -1 to 100bar (-1 to 1,500psi), with a barometric reference option available for absolute pressure emulation. Additionally an IntelliScale option can be ordered to provide IS-50 accuracy of 0.025 % of reading in the upper half of the measuring range. This option also provides an enhanced accuracy on the lower 50% of the module range.
The 7030B user interface has an intuitive touch screen to enable fast and simple operation. EasyCal software can also be used with the unit to fully automate the calibration process, providing control and read back during testing applications.
Applications
With excellent control stability of 0.003%, precision of 0.015% and a 12 month uncertainty of 0.025% full scale (IS-50 optional), the 7030B is well suited for industrial calibration of pressure sensors and transmitters, or as a working standard for the control and calibration of all types of pressure gauges.
Functionality
The module features a colour touch-screen interface with user-friendly menus designed for simple operation, enabling users to quickly learn and master the operation and controls. Depending on the application, the user can choose between three input functions:
- Numeric keypad for the precise input of the pressure value (set point) which will be controlled.
- The STEP key menu provides defined steps programmed in pressure increments or percent of full span to move the pressure set point across the range of the instrument under test. Step key values are user defined in the setup menu.
- The JOG key menu provides a way for the operator to define small pressure steps up or down to reach a cardinal point on a dial gauge. The jog buttons increment the least significant digit by 1, 10 or 100 counts.
EasyCal Software
The 7030B is EasyCal Software compatible, enabling automatic calibration to increase speed and efficiency of work. EasyCal controlled calibration significantly decreases testing times, meaning less instrument downtime and faster turnaround. In addition EasyCal has features to manage and administrate both inventory and quality control, so it gives users the platform for their entire calibration program.
In a CalBench, EasyCal can be used on a control centre or 7051 module, that is conveniently positioned centrally in the primary console with the 7030B located to the side. This provides a solution that is both automated and ergonomic, ideal for workshops and laboratories that require an organized workspace.
Thông số kỹ thuật
Pressure ranges | -1 to +100 bar (depending on range ordered) |
Pressure Types | Absolute, gauge or bi-directional ranges |
Precision | < 0.015% FS (0.015% IS with 7030INTSC option) |
1 year Uncertainty | < 0.025% FS (0.025% IS-50 with 7030INTSC option) |
IntelliScale Option | 0.025 % IS-50 Accuracy: 0.025 % of reading in the upper half of the measuring range, and 0.025% from 50% of max to the minimum range, ie 0.025% of 50% of the ordered range. 0.015 % IS Precision – Defined as the max deviation between two measurements at one point under lab conditions, including linearity, hysteresis & repeatability of the measuring instrument. Note: IS-50 only available on bi-directional models 10bar & above, gauge & absolute models 1bar & above. |
Barometric Reference Option | The barometric reference can be used to switch pressure types, absolute <=> gauge. With gauge pressure sensors, the measuring range of the sensors must begin with -1bar (-15psi) in order to carry out an absolute pressure emulation. Measuring range: 552 to 1,172 mbar abs. (8 to 17 psi abs) / Accuracy: 0.02 % of reading |
Pressure units | 38 selectable and 2 programmable |
Control stability | 0.003% of range |
Slew rate | 3 seconds to stable flag (+/-0.025% full scale pressure) for a 10% pressure change typical into 150cc volume at pressures greater than 0.34bar (5 PSI). Larger volumes can lengthen this time. Controlling to pressures less than atmosphere can lengthen this time. |
Control range | Maximum from 0 up to 100% FS |
Overshoots | < 1 % FS in high speed mode |
Test volume | 50 to 1,000ccm (without throttle) |
Pressure ports | Quick release (20bar and under), Minimess (above 20bar) |
Filter elements | 30 micron filter element included in each pressure port |
Pressure media | Clean dry non-corrosive gases |
Wetted parts | Aluminium, brass, 316 and 316L stainless steel, Buna N, FPM/FKM, glass filled epoxy, RTV, Nylon |
Overpressure protection | Safety relief valve |
Screen | Colour LCD with touch-screen |
Resolution | 4 to 6 digtis |
Display update | 4 values/sec |
Warm-up time | approx. 15 minutes |
Digital Interface | RS-232, USB |
Command sentences | SCPI |
Power Supply | 100 to 230V AC, 50/60 Hz, as per CalBench supplied |
Supply port Pressure | Maximum 105 to 110% FS |
Test port Pressure | Maximum 105% FS |
Operating temperature | 0 to 50°C |
Storage temperature | 0 to 70°C |
Air humidity | 5 to 95% (relative humidity without moisture condensation) |
Compensated temperature range | 15 to 45°C |
Module Width | 295mm (primary console fitting only) |