7054 & 7055 High Voltage Adjustable Power Supply Modules

7054 & 7055 High Voltage Adjustable Power Supply Modules

  • Description
  • Reviews (0)

Description

Precision linear regulated DC power supplies with high power density and smart analog controls for voltages up to 120V (7054) or 250V (7055).

Comprehensive features include:

  • Linear regulation: ultra-low output noise and fast transient recovery
  • High power density: 90 watts per output from the 7054 and 94 watts per output from the 7055
  • Higher precision: Exceptional line and load regulation; easy-switch remote sense
  • Better metering: High accuracy four digit fixed-resolution meters; low current range; current meter averaging
  • True analog controls: Quick and intuitive adjustment of voltage and current
  • Digital convenience: Unique S-Lock and V-Span functions
  • See exactly what’s happening: DC output switch – check your settings before applying them; ‘view settings’ button – check and adjust limits at any time
  • Safe and secure to use: Lockable voltage and current settings (using S-Lock); connect via safety binding-post terminals.
  • Programmable versions 7054P and 7055P: Includes all of the manual control features, but adds comprehensive remote control facilities. RS-232 and USB interfaces.

Thông số kỹ thuật

Voltage/Current Ranges 7054 – 0 to 120V / 0.01mA to 750mA (90W max.)
7055 – 0 to 250V / 0.01mA to 375mA (94W max.)
Note: Actual maxima for voltage and current are typically 1% greater than the figures given above except for the voltage control on the 7055 which is limited to 250.0V
Output Setting & Control Voltage Setting: By coarse and fine controls.
Current Setting: By single logarithmic control.
Low Current Range: Reduces max. current to 75mA and increases resolution to 0.01mA.
Output Mode: Constant voltage or constant current with automatic cross-over. CC indicator lit in constant current mode.
Output Switch: Electronic, non isolating. Preset voltage & current limit displayed when Output is off. Output rise time no load <20ms.
View Settings: With the output On, the meters show actual voltage and current. The preset levels can be viewed and adjusted at any time by pressing the View Settings button.
V-Span
(Voltage Span Control)
Voltage adjustment range can be controlled by digital setting of the end-stop values of the coarse voltage control to any desired values. The range for Vmax is 1V to 120V or 250V depending on model. The range for Vmin is 0 to (Vmax – 1V).
S-Lock (Settings Lock) Voltage and current settings can be locked by a single button press. Lock accuracy is equal to the meter accuracy (see Meter Specification).
Output Performance Ripple & Noise: Normal mode voltage: <2mV rms and 10mV p-p. Normal mode current: <10uA rms ; <1uA rms on 75mA range. Common mode current: <20uA rms
Load Regulation: Voltage <0·01% + 10mV. Current – typically 0·01% + 50μA.
Line Regulation: Voltage <0·01% + 10mV for 10% line change. Current <0·01% + 50μA. for 10% line change.
Transient Response: <250μs to within 50mV of setting for a 90% load change.
Temp. Coefficient: Voltage: typically <(50ppm + 2mV)/°C Current: typically <(100ppm + 0.1mA)/°C; <(100ppm + 0.01mA)/°C on 75mA range.
Output Protection Output Protection: Output will withstand forward voltages of up to rated output voltage. Reverse protection by diode clamp for currents to 3A.
OVP and OCP Trips: Voltage or current measured to be in excess of 105% of the rated maximum will cause the output to trip off.
Over-temperature: Output trips off for over-temperature.
Safety Interlocks: Operations that could cause an unexpected change in voltage or current settings are interlocked with the output switch.
Output Connections Output Terminals: Universal 4mm safety binding posts on 19mm (0.75″) spacing. Terminals can accept fixed shroud 4mm plugs, standard 4mm plugs, fork terminals and bare wires.
Remote Sense Sense Selection: Voltage sensing can be selected as Local or Remote by front panel switch.
Sense Terminals: Sprung loaded screw-less terminals.
Display Type Dual 4-digit meters, 10mm (0.39”) LED.
Voltage Meter Resolution: 100mV
Accuracy: ± (0.1% of reading + 100mV)
Current Meter Resolution: 0.1mA (0·01mA on 75mA range)
Accuracy: ± (0·3% + 0.3mA); ± (0·3% + 0·03mA) on 75mA range
Meter Damping Normally 20ms, switchable to 2 sec for averaging rapidly varying loads.

Versions 7054: 120V DC 750mA Adjustable Power Supply
7054P: 7054 Programmable Version – RS-232/USB (see data sheet in download tab for specifications)
7055: 250V DC 375mA Adjustable Power Supply
7055P: 7055 Programmable Version  – RS-232/USB (see data sheet in download tab for specifications)
Module Widths 7054, 7054P, 7055 and 7055P: 150mm (Both modules can only be fitted in the CalBench primary console)

Reviews

There are no reviews yet.


Be the first to review “7054 & 7055 High Voltage Adjustable Power Supply Modules”