Specifications |
ORing Bypass Switch Model |
IBS-102FX-SS-LC |
IBS-102FX-MM-LC |
Physical Ports |
|
|
LC connector |
4 Duplex Single-mode LC connector |
4 Duplex Multi-mode LC connector |
Fiber Ethernet |
|
|
Optical Fiber |
Single-mode: 9/125μm |
Multi-mode: 50/125μm or 62.5/125μm |
Operating Wavelength |
1260 ~ 1570 nm |
780 ~ 1350 nm |
Insert loss |
typical1.2 dB , Maximun 1.6 dB |
< 1.0 dB |
Switch time |
< 10ms |
< 10ms |
DIP Switch Settings |
|
|
DIP Swicth No.1 |
Power-1 failed warning detection – (On) relay enable (Off) relay disable |
DIP Swicth No.2 |
Power-2 failed warning detection – (On) relay enable (Off) relay disabl |
LED Indicators |
|
|
Power Indicator |
Green : Power LED x 2 |
Normal indicator |
Green On : Operated in normal mode |
Fault indicator |
Amber : Indicates power failure occurred |
Fault contact |
|
|
Relay |
Relay output for power failure warning |
Power |
|
|
Redundant Input Power |
Dual 12~48 VDC power inputs at DC-Jack and 4-pin terminal block |
Power Consumption (Typ.) |
2.7 watts |
2.7 watts |
Overload Current Protection |
Present |
Reverse Polarity Protection |
Present on terminal block |
Physical Characteristics |
|
|
Enclosure |
IP-30 |
Dimensions (W x D x H) |
26.1(W) x 94.9(D) x 144.3(H) mm (1.03 x 3.74 x 5.68 inch.) |
Weight (g) |
405 g |
405 g |
Environmental |
|
|
Storage Temperature |
-40 to 85°C (-40 to 185°F) |
Operating Temperature |
-40 to 70°C (-40 to 158°F) |
Operating Humidity |
5% to 95% Non-condensing |
|
Regulatory Approvals |
|
|
EMI |
FCC Part 15, CISPR (EN55022) class A, |
EMS |
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 |
Shock |
IEC60068-2-27 |
Free Fall |
IEC60068-2-32 |
Vibration |
IEC60068-2-6 |
Safety |
EN60950-1 |
Warranty |
5 years |