5018 Programmable DC/AC V/I Calibrator

  • Mô tả
  • Đánh giá (0)

Mô tả

High Accuracy Programmable DC/AC Source
The 5018 is a versatile instrument that covers a wide range of applications. It can be configured as a simple benchtop DC voltage source or advanced AC/DC voltage and current calibrator controlled via PC or laptop, performing any number of tasks as part of a complex ATE test rig.

Ramping Feature
The 5018 includes an internal ramping feature. A ramp rate per range for each function can be set via a PC. The option to ramp the output can be turned on or off via the front panel. This is particularly useful in aviation and automotive industries for testing analogue gauges.

Simple Operation and Clear Visual Display
Simple front panel operation allows the user to quickly set the function and output required. Using the jog / shuttle dial deviation the user can finely adjust the output value as a percentage (+/- 99.99%). All this information is shown on a clear, easy to read LED display.

GPIB, RS-232, and USB Interfaces
These interfaces allow the 5018 to be connected to a PC and controlled by an external program such as Time Electronics’ EasyCal calibration software. The 5018 uses a SCPI command structure for programming. This makes writing control programs in Visual Basic, C and Labview a simple task.

EasyCal Software – Manage, Automate and Optimise the Calibration Process
Connect the 5018 to a PC or laptop (via RS-232, GPIB or USB) installed with Time Electronics EasyCal software and automate the calibration process. Increase speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards.

EasyCal has the ability to control a wide range of programmable instruments and comprehensive ATE systems can be configured to control a variety of applications. It has full read back capability and therefore can perform closed loop testing. Conditional tests can be configured to allow decision making to further enhance the usefulness.

Thông số kỹ thuật

Range Accuracy 1 year Output Resistance Max Output Current Resolution
22mV (33mV) 30ppm + 4μV 10Ω (50Ω) 100nV
220mV (330mV) 15ppm (30ppm) + 6μV 10Ω (50Ω) 1μV
2.2V (3.3V) 15ppm (20ppm)+ 20μV < 0.15Ω 20mA 1μV
22V (30V) 15ppm (20ppm) + 150μV < 0.15Ω 20mA 10μV

Range Accuracy 1 year Output Resistance Max Output Current Resolution
220V* 15ppm + 1mV <0.25Ω 10mA 100μV
1kV* 25ppm + 3mV <1Ω 1mA 1mV

*Minimum Load 20kΩ

Range Accuracy 1 year Compliance Voltage Resolution
220μA 150ppm + 15nA 11V 1nA
2.2mA 100ppm + 40nA 11V 10nA
22mA 80ppm + 200nA 11V 10nA
220mA 80ppm + 3μA 11V 100nA
Range RMS Acc % 1yr 10Hz – 1kHz Acc % 1 yr 1kHz – 10kHz Acc % 1yr 10kHz – 20kHz Output Resistance Max Output Current
22mV 0.05% + 100μV 0.05% + 150μV 0.05% + 250μV 10Ω
220mV 0.04% + 100μV 0.04% + 150μV 0.04% + 250μV 10Ω
2.2V 0.03% + 170μV 0.03% + 250μV 0.03% + 300μV <0.15Ω 20mA
22V 0.03% + 2.0mV 0.03% + 3.0mV 0.03% + 4.0mV <0.15Ω 20mA
Range RMS Accuracy 1 year Compliance Voltage RMS Resolution
220μA 0.07% + 300nA 5V 10nA
2.2mA 0.05% + 300nA 5V 10nA
22mA 0.05% + 3μA 5V 100nA
220mA 0.05% + 30μA 5V 1μA

Full details on the available external options are shown in the Models / Options tab.

 

Warm up 1 hour to full accuracy
Settling Time Less than 5 seconds
Standard Interfaces GPIB (IEEE-488), RS-232, USB
Temp Performance Operating: 10 to 40°C, Full Spec: 23°C +/- 5°C, Storage: -10°C to 50°C
Operating Humidity < 80% non condensing
Operating Altitude 0 to 3km. Non operating 3 to 12km
Line Power 100 – 230V AC 50/60 Hz. Power Consumption 60W typical, 80W Max.
Dimensions W450 x D272 x H152mm (18 x 11 x 7”)
Weight 8.2Kg (18lbs)
Country of Origin UK
Supplied With User manual, RS-232 cable, and USB adaptor/cable

Đánh giá

Chưa có đánh giá nào.


Hãy là người đầu tiên nhận xét “5018 Programmable DC/AC V/I Calibrator”