IMC-P111FX / IMC-P111P M12 Series
- Description
- Reviews (0)
Description
Specifications | |||
ORing Media Converter Model |
IMC-P111FX-MM-SC-M12 |
IMC-P111FX-SS-SC-M12 |
IMC-P111P-M12 |
Physical Ports | |||
10/100 Base-T(X) Port in RJ45 Auto MDI/MDIX |
1 (M12 A-coded) | 1 (M12 A-coded) | 1 (M12 A-coded) |
Fiber Ports Number | 1 | 1 | – |
Fiber Ports Standard | 100Base-FX | 100Base-FX | – |
Fiber Mode | Multi-mode | Single-mode | – |
Fiber Diameter (µm) | 62.5/125 µm 50/125 µm |
9/125 µm | – |
Fiber Optical Connector | SC | SC | – |
Typical Distance (Km) | 2 Km | 30 Km | – |
Wavelength (nm) | 1310 nm | 1310 nm | – |
Max. Output Optical Power (dbm) | -14 dbm | -8 dbm | – |
Min. Output Optical Power (dbm) | -23.5 dbm | -15 dbm | – |
Max. Input Optical Power (Saturation) | 0 dbm | 0 dbm | – |
Min. Input Optical Power (Sensitivity) | -31 dbm | -34 dbm | – |
Link Budget (db) | 7.5 db | 19 db | – |
100Base-FX SFP Port | – | – | 1 |
Ethernet Standards | IEEE 802.3 for 10Base-T IEEE 802.3u for 100Base-T(X) and 100Base-FX IEEE 802.3x for Flow control |
||
Processing | Store-and-Forward | ||
DIP-Switch setting | DIP-Switch 1 for LFP mode selection : (ON) enable / (OFF) disable DIP-Switch 2 for Ethernet speed selection : (ON)10Mbps / (OFF) 10/100Mbps Auto-negotiate DIP-Switch 3 for Ethernet full/half duplex selection : (ON) Half-duplex / (OFF) Full/Half-Duplex Auto-negotiate DIP-Switch 4 for fiber full/half duplex selection : (ON) Half-Duplex / (OFF) Full-Duplex |
||
Alarm DIP-Switch | |||
DIP-Switch 1 | Power-1 failed warning : (ON) enable, (OFF) disable | ||
DIP-Switch 2 | Power-2 failed warning : (ON) enable, (OFF) disable | ||
LED Indicators | |||
Power indicator | LV Model : Green : Power LED x 3 (ON : power input on-line / (OFF) power input off-line HV Model : Green : Power LED x 2 (ON : power input on-line / (OFF) power input off-line |
||
10/100Base-T(X) RJ45 port indicator | Green for port Link/Act – (ON) Link up / (Blinking) Acting / (OFF) Link down Amber for port duplex indicator – (ON) Full-Duplex / (OFF) Half-Duplex |
||
100Base-FX fiber port indicator | Green for fiber port Link/Act – (ON) Link up / (Flash) Acting / (OFF) Link down Green for fiber port duplex indicator – (ON) Full-Duplex / (OFF) Half-Duplex |
||
LFP statue indicator | Amber LED – (ON) LFP function fail / (OFF) LFP function disable | ||
Fault Indicator | Amber : Indicate unexpected event occurred | ||
Duplex indicator | Green for port duplex indicator – (ON) Full-Duplex / (OFF) Half-Duplex | ||
Power | |||
LV Model Input Power | Triple DC inputs. 12~48VDC on 7-pin terminal block. 12~45VDC on power jack | ||
HV Model Input Power | Dual 100~240VAC power inputs on 8-pin terminal block | ||
Power consumption (Typ.) | LV model : 12 Watts, HV model : 100VAC/4.8Watts, 240VAC/5.8Watts) | LV model : 12 Watts HV model : 100VAC/4.8Watts, 240VAC/5.8Watts) |
LV model : 12 Watts HV model : 100VAC/4.8Watts, 240VAC/5.8Watts) |
Overload current protection | Present | ||
Reverse polarity protection | Present on terminal block | ||
Physical Characteristics | |||
Enclosure | IP-30 | ||
Dimension (W x D x H) | 54.2(W) x 106.1(D) x 145.4(H) mm (2.05×4.18×5.68 inch.) | ||
Weight (g) | LV model : 691 g HV model : 833 g |
LV model : 681 g HV model : 823 g |
|
Environmental | |||
Storage Temperature | -40 to 85°C (-40 to 185°F) | ||
Operating Temperature | -40 to 85°C (-40 to 185°F) | ||
Operating Humidity | 5% to 95% Non-condensing | ||
Regulatory Approvals | |||
Power Automation | IEC 61850-3, IEEE 1613 | ||
EMI | FCC Part 15, CISPR (EN55022) class A, EN50155 (EN50121-3-2, EN50121-4 | ||
EMS | EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 | ||
Shock | IEC60068-2-27 | ||
Free Fall | IEC60068-2-32 | ||
Vibration | IEC60068-2-6 | ||
Safety | EN60950-1 | ||
Warranty | 5 years |
Reviews
There are no reviews yet.